50 research outputs found

    Results of 102 cases of complete repair of congenital heart defects in patients weighing 700 to 2500 grams

    Get PDF
    AbstractBackground: Published data suggest that low birth weight is a risk factor for poor outcome in corrective surgery for many cardiac defects. Congenital heart defects in low birth weight infants are typically managed with supportive therapy or palliative operations, with definitive repair delayed. The morbidity associated with such approaches is high. Methods: Since 1990 complete repair of congenital heart defects (other than patent ductus arteriosus) has been performed in 102 infants no larger than 2500 g (median 2100 g, range 700-2500 g), including 16 no larger than 1500 g. Defects included ventricular septal defect (n = 22), tetralogy of Fallot complexes (n = 20), transposition complexes (n = 13), aortic coarctation (n = 12), interrupted arch (n = 10), truncus arteriosus (n = 8), atrioventricular septal defect (n = 6), total anomalous pulmonary venous return (n = 5), and other (n = 6). Results: Preoperative morbidity was more common among patients referred late for surgical correction. There were 10 early deaths (10%) attributable to cardiac failure (n = 4), arrhythmia (n = 1), multiorgan failure (n = 1), sepsis (n = 1), idiopathic coronary artery intimal necrosis (n = 1), foot gangrene (n = 1), and pulmonary hemorrhage (n = 1). No patient had postbypass intracerebral hemorrhage. At follow-up (median 36 months) there were 8 late deaths, and 8 patients underwent 10 reinterventions. There was no evidence of neurologic sequelae attributable to the operation. Conclusions: In general, delaying repair of congenital heart defects in low birth weight infants does not confer a benefit and is associated with higher preoperative morbidity. Complete repair of both simple and complex lesions can be achieved in such cases with good results. Growth after repair approximates the normal curve for low birth weight infants without heart disease. It is recommended that such infants, especially when they have symptoms, undergo early surgical repair rather than prolonged medical management or other forms of palliation. (J Thorac Cardiovasc Surg 1999;117:324-31

    Intermediate follow-up following intravascular stenting for treatment of coarctation of the aorta

    Full text link
    Background : We report a multiinstitutional study on intermediate-term outcome of intravascular stenting for treatment of coarctation of the aorta using integrated arch imaging (IAI) techniques. Methods and Results : Medical records of 578 patients from 17 institutions were reviewed. A total of 588 procedures were performed between May 1989 and Aug 2005. About 27% (160/588) procedures were followed up by further IAI of their aorta (MRI/CT/repeat cardiac catheterization) after initial stent procedures. Abnormal imaging studies included: the presence of dissection or aneurysm formation, stent fracture, or the presence of reobstruction within the stent (instent restenosis or significant intimal build-up within the stent). Forty-one abnormal imaging studies were reported in the intermediate follow-up at median 12 months (0.5–92 months). Smaller postintervention of the aorta (CoA) diameter and an increased persistent systolic pressure gradient were associated with encountering abnormal follow-up imaging studies. Aortic wall abnormalities included dissections ( n = 5) and aneurysm ( n = 13). The risk of encountering aortic wall abnormalities increased with larger percent increase in CoA diameter poststent implant, increasing balloon/coarc ratio, and performing prestent angioplasty. Stent restenosis was observed in 5/6 parts encountering stent fracture and neointimal buildup ( n = 16). Small CoA diameter poststent implant and increased poststent residual pressure gradient increased the likelihood of encountering instent restenosis at intermediate follow-up. Conclusions : Abnormalities were observed at intermediate follow-up following IS placement for treatment of native and recurrent coarctation of the aorta. Not exceeding a balloon:coarctation ratio of 3.5 and avoidance of prestent angioplasty decreased the likelihood of encountering an abnormal follow-up imaging study in patients undergoing intravascular stent placement for the treatment of coarctation of the aorta. We recommend IAI for all patients undergoing IS placement for treatment of CoA. © 2007 Wiley-Liss, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/57392/1/21191_ftp.pd

    Regional heterogeneity and firms’ innovation: the role of regional factors in industrial R&D in India

    Get PDF
    This study makes an early attempt to estimate the magnitude and intensity of manufacturing firms’ R&D by Indian states during the period 1991‒2008 and analyses the role of regional factors on firm-level R&D activities. As there is little research on state-wise R&D performance of firms in India, this study serves an important contribution to the academic and policy realm. It has brought out the fact the total manufacturing R&D investment in India is unevenly distributed regionally with a few states accounting for disproportionate share of it. Regional heterogeneity or inter-state disparities in R&D has increased between the 1990s and the first decade of the twenty-first century. In view of this persistent regional heterogeneity in R&D, the study has developed and estimated an empirical model for a sample of 4545 Indian manufacturing firms with R&D facilities located in single state and that explicitly includes regional factors as probable factors affecting R&D. The three-step Censored Quantitle Regression results confirm that regional factors play an important role in shaping the R&D intensity of the sample of firms. This led us to some useful policy suggestions for regional governments to promote local firms’ R&D activities
    corecore